HZG 50Hz AC DC Power Frequency Withstand Voltage Test Set
50Hz AC DC Power Frequency Testing Voltage Test Set

Uvod
Ovaj tester otpornog napona na frekvenciji napajanja koristi naprednu proizvodnu opremu i novu tehnologiju epoksidnog vakuumskog izlivanja zavojnica i gvozdenog jezgra tipa CD-, koji očigledno smanjuju težinu i zapreminu, poboljšavaju izolacionu čvrstoću i nivo otpornosti na vlagu, efikasno slabe magnet za curenje što uvelike povećava sposobnost izdržavanja uticaja ispitivanja struje kratkog spoja transformatora.
Tehnički podaci
Model | Kapacitet (KVA) | Ulazni napon (V) | Izlazni napon (KV) | Izlazna struja (mA) | Izlaz DC visokog napona (KV) | Max. Vanjska dimenzija (mm) | Težina (kg) |
HZG-1,5/50 | 1.5 | 200 (400) | 50 | 30 | 70 | 250x180x370 | 13 |
HZG-3/50 | 3 | 60 | 330x270x600 | 30 | |||
HZG-5/50 | 5 | 100 | 400x330x700 | 48 | |||
HZG-6/50 | 6 | 120 | 300x310x680 | 46 | |||
HZG-10/50 | 10 | 200 | 430x370x750 | 73 | |||
HZG-20/50 | 20 | 400 | 470x370x750 | 85 | |||
HZG-30/50 | 30 | 600 | 500x380x780 | 120 | |||
HZG-5/100 | 5 | 100 | 50 | 140 | 430x370x1050 | 67 | |
HZG-10/100 | 10 | 100 | 470x370x1050 | 80 | |||
HZG-20/100 | 20 | 200 | 510x410x880 | 120 | |||
HZG-30/100 | 30 | 300 | 580x380x880 | 160 | |||
HZG-50/100 | 50 | 500 | 650x460x1010 | 230 |
Ova serija kontrolnih kutija dizajnirana je i proizvedena prema jedinstvenom opsegu upotrebe visokonaponskih ispitnih transformatora.
The capacity of the control box is nominated as the capacity of the voltage regulator and the voltage regulator. If it works with the test transformer (working system within 30 minutes in a short time), it can be matched according to the provisions of the power industry standard of the People's Republic of China "DL474.4-92": P=0.75P. P-test transformer capacity and P-regulator capacity. If it is used for batch test of electrical equipment factory products, the capacity of voltage regulator should be equal to the capacity of test transformer, that is,P0=P.
Tehnički parametri kontrolne kutije prikazani su u tabeli 1.
1. Rated capacity: 10kVA
2. Input voltage: 220V
3. Input current: 45.5A
4. Output voltage: 0-250V
5. Weight: 30kg
6. Dimensions: 400X320X390(mm)
Nakon{0}}usluga
Within one year from the date of purchase, the instrument belongs to the company's product quality problems for free maintenance, providing maintenance and technical services for life. If the instrument is found to be abnormal or malfunctioning, please contact the company in time to arrange the most convenient treatment plan and provide you with the fastest on-site service.



Popularni tagovi: HZG 50Hz AC DC Power Frequency Withstand Voltage Test Set, China, suppliers, manufacturers, price, for sale, ac dielectric withstand test voltage, Power Frequency Withstand Voltage Tester, dielectric withstanding voltage test equipment, Power Frequency Withstand Voltage Test System, Pressure test AC 70kV, ac withstanding voltage testes up to 50kv, ac power frequency withstand tester, AC / DC High Voltage Breakdown Tester
Pošaljite upit